logo
Products
PRODUCTS DETAILS
Home > Products >
Plug-and-Play North Finding Instrument RS232/RS422/Ethernet, 0.03° Accuracy, Indoor/Outdoor Azimuth Reference for UAV Ground Test, Heli & Antenna Alignment

Plug-and-Play North Finding Instrument RS232/RS422/Ethernet, 0.03° Accuracy, Indoor/Outdoor Azimuth Reference for UAV Ground Test, Heli & Antenna Alignment

MOQ: 1
Standard Packaging: 60CM *50CM*50Cm
Delivery Period: 1Week
Payment Method: T/T
Supply Capacity: 10PCS/Week
Detail Information
Place of Origin
hubei
Brand Name
CSSC
Certification
RDG02541573
Model Number
DP-Z2
Highlight:

North Finding Instrument RS232/RS422/Ethernet

,

0.03° Accuracy Azimuth Reference UAV

,

IMU Inertial Measurement Unit Alignment

Product Description



DP-Z2 North Finder – Technical Specification

1. Overview

The MFN01L North Finder (hereinafter referred to as "the instrument" or "the device") is an intelligent orientation instrument. It employs a high-precision gyroscope to acquire spatial 3-axis parameters and achieve automatic north-seeking.

2. Environmental Requirements

① Operating temperature: (0 ~ 40) ℃

② Humidity: ≤ 95%

③ Atmospheric pressure: (86 ~ 116) kPa

④ Storage temperature: (-40 ~ 60) ℃

⑤ Environment free from significant vibration and shock.

3. Technical Parameters

3.1 Operating Voltage and Current

① Operating voltage: (9 ~ 36) V DC

② Current: ≤ 0.5 A

3.2 Measurement Range

① Azimuth range: (0 ~ 360)°

② Pitch (tilt) angle range: (-90 ~ 90)°

③ Roll angle range: (-180 ~ 180)°

3.3 Basic Error

  • Azimuth error: ±0.03°

  • Pitch (tilt) angle error: ±0.1°

  • Roll angle error: ±0.1°

3.4 North-Seeking Time

≤ 180 s

3.5 Other Parameters

  • Tilt tolerance: During north-seeking on uneven hard ground, tilt ≤ 15°

4. Interface Definition

The MFN01L North Finder charging port and data output port adopt the electrical connector ZLN.102F.309.CLL.

Figure 1 – Interface Pin Arrangement

Table 1 – Interface Definition

Pin No.

RS422 Interface Definition

Remarks

1

422_GND

RS422 signal ground

2

GND

Ground signal input

3

GND

Ground signal input

4

VIN

Power supply positive input

5

VIN

Power supply positive input

6

RS422_RX-

RS422 RX- terminal

7

RS422_RX+

RS422 RX+ terminal

8

RS422_TX-

RS422 TX- terminal

9

RS422_TX+

RS422 TX+ terminal

5. Dimensions and Weight

① Dimensions: 100 mm × 80 mm × 70 mm (main housing)

② Weight: ≤ 0.8 kg

(MFN01L Outline Drawing)

6. Instrument Usage Requirements

6.1 Operating Conditions and Precautions

Before use, the operator must carefully read this manual to fully understand the instrument's purpose, application scope, performance, and main technical indicators. Only then proceed with operation. The instrument should be regularly maintained as required to ensure measurement accuracy and service life.

6.2 Angle Measurement Procedure

Angle measurement consists of two main steps:

① Automatic North-Seeking:​ Power on the instrument and connect it to a computer via data cable. Launch the host PC software. Place the instrument as level as possible on a hard, stable surface at the measurement site. Once the instrument is firmly fixed, initiate north-seeking from the measurement interface. Wait patiently for the automatic north-seeking process to complete.

Caution:​ Do NOT move, shake, or disturb the instrument during north-seeking. Any vibration will cause inaccurate results or abnormal azimuth readings!

② Angle Measurement:​ After the pitch angle and azimuth values stabilize on the display, read the measurement values or save the angle data as needed.

6.3 Important Notices

① This instrument contains precision internal components. Handle with care. Do NOT collide, vibrate, drop, or strike the instrument!

② For best measurement accuracy, it is recommended to perform a new north-seeking cycle before each measurement session.

7. Operation Instructions

7.1 Key Functions

After launching the host PC software, the system initializes and enters the angle measurement interface (Figure 2). In the measurement interface, selecting "Return" and pressing the OK key returns to the main function menu (Figure 3). In the main interface, use the direction keys "▲" or "▼" to select functions, press "OK" to enter the corresponding function screen, or press "Return" to go back to the previous screen or function.

(Figure 2)(Figure 3)

7.3 Measurement Function

After normal power-on, the device enters the measurement interface by default (Figure 4). The measurement screen is divided into real-time measurement display area, north-seeking status, and function option display areas.


🔧 Quick Spec Summary (for Google/B2B listing)

Item

Value

Model

MFN01L

Azimuth Accuracy

±0.03°

Pitch/Roll Accuracy

±0.01°

North-Seeking Time

≤ 180 s

Voltage

9–36 V DC

Current

≤ 0.5 A

Interface

RS422

Dimensions

100×80×70 mm

Weight

≤ 0.8 kg

Operating Temp.

0 ~ 40 °C

Storage Temp.

-40 ~ 60 °C

Tilt Tolerance

≤ 15°


We offer a wide accuracy range from 0.5° down to 0.01°, with fully customizable options to suit your unique application.

Products
PRODUCTS DETAILS
Plug-and-Play North Finding Instrument RS232/RS422/Ethernet, 0.03° Accuracy, Indoor/Outdoor Azimuth Reference for UAV Ground Test, Heli & Antenna Alignment
MOQ: 1
Standard Packaging: 60CM *50CM*50Cm
Delivery Period: 1Week
Payment Method: T/T
Supply Capacity: 10PCS/Week
Detail Information
Place of Origin
hubei
Brand Name
CSSC
Certification
RDG02541573
Model Number
DP-Z2
Minimum Order Quantity:
1
Packaging Details:
60CM *50CM*50Cm
Delivery Time:
1Week
Payment Terms:
T/T
Supply Ability:
10PCS/Week
Highlight

North Finding Instrument RS232/RS422/Ethernet

,

0.03° Accuracy Azimuth Reference UAV

,

IMU Inertial Measurement Unit Alignment

Product Description



DP-Z2 North Finder – Technical Specification

1. Overview

The MFN01L North Finder (hereinafter referred to as "the instrument" or "the device") is an intelligent orientation instrument. It employs a high-precision gyroscope to acquire spatial 3-axis parameters and achieve automatic north-seeking.

2. Environmental Requirements

① Operating temperature: (0 ~ 40) ℃

② Humidity: ≤ 95%

③ Atmospheric pressure: (86 ~ 116) kPa

④ Storage temperature: (-40 ~ 60) ℃

⑤ Environment free from significant vibration and shock.

3. Technical Parameters

3.1 Operating Voltage and Current

① Operating voltage: (9 ~ 36) V DC

② Current: ≤ 0.5 A

3.2 Measurement Range

① Azimuth range: (0 ~ 360)°

② Pitch (tilt) angle range: (-90 ~ 90)°

③ Roll angle range: (-180 ~ 180)°

3.3 Basic Error

  • Azimuth error: ±0.03°

  • Pitch (tilt) angle error: ±0.1°

  • Roll angle error: ±0.1°

3.4 North-Seeking Time

≤ 180 s

3.5 Other Parameters

  • Tilt tolerance: During north-seeking on uneven hard ground, tilt ≤ 15°

4. Interface Definition

The MFN01L North Finder charging port and data output port adopt the electrical connector ZLN.102F.309.CLL.

Figure 1 – Interface Pin Arrangement

Table 1 – Interface Definition

Pin No.

RS422 Interface Definition

Remarks

1

422_GND

RS422 signal ground

2

GND

Ground signal input

3

GND

Ground signal input

4

VIN

Power supply positive input

5

VIN

Power supply positive input

6

RS422_RX-

RS422 RX- terminal

7

RS422_RX+

RS422 RX+ terminal

8

RS422_TX-

RS422 TX- terminal

9

RS422_TX+

RS422 TX+ terminal

5. Dimensions and Weight

① Dimensions: 100 mm × 80 mm × 70 mm (main housing)

② Weight: ≤ 0.8 kg

(MFN01L Outline Drawing)

6. Instrument Usage Requirements

6.1 Operating Conditions and Precautions

Before use, the operator must carefully read this manual to fully understand the instrument's purpose, application scope, performance, and main technical indicators. Only then proceed with operation. The instrument should be regularly maintained as required to ensure measurement accuracy and service life.

6.2 Angle Measurement Procedure

Angle measurement consists of two main steps:

① Automatic North-Seeking:​ Power on the instrument and connect it to a computer via data cable. Launch the host PC software. Place the instrument as level as possible on a hard, stable surface at the measurement site. Once the instrument is firmly fixed, initiate north-seeking from the measurement interface. Wait patiently for the automatic north-seeking process to complete.

Caution:​ Do NOT move, shake, or disturb the instrument during north-seeking. Any vibration will cause inaccurate results or abnormal azimuth readings!

② Angle Measurement:​ After the pitch angle and azimuth values stabilize on the display, read the measurement values or save the angle data as needed.

6.3 Important Notices

① This instrument contains precision internal components. Handle with care. Do NOT collide, vibrate, drop, or strike the instrument!

② For best measurement accuracy, it is recommended to perform a new north-seeking cycle before each measurement session.

7. Operation Instructions

7.1 Key Functions

After launching the host PC software, the system initializes and enters the angle measurement interface (Figure 2). In the measurement interface, selecting "Return" and pressing the OK key returns to the main function menu (Figure 3). In the main interface, use the direction keys "▲" or "▼" to select functions, press "OK" to enter the corresponding function screen, or press "Return" to go back to the previous screen or function.

(Figure 2)(Figure 3)

7.3 Measurement Function

After normal power-on, the device enters the measurement interface by default (Figure 4). The measurement screen is divided into real-time measurement display area, north-seeking status, and function option display areas.


🔧 Quick Spec Summary (for Google/B2B listing)

Item

Value

Model

MFN01L

Azimuth Accuracy

±0.03°

Pitch/Roll Accuracy

±0.01°

North-Seeking Time

≤ 180 s

Voltage

9–36 V DC

Current

≤ 0.5 A

Interface

RS422

Dimensions

100×80×70 mm

Weight

≤ 0.8 kg

Operating Temp.

0 ~ 40 °C

Storage Temp.

-40 ~ 60 °C

Tilt Tolerance

≤ 15°


We offer a wide accuracy range from 0.5° down to 0.01°, with fully customizable options to suit your unique application.

sitemap |  Privacy Policy | China Good Quality Laser Inertial Navigation System Supplier. Copyright © 2025-2026 CSSC Star&Inertia Technology co.,ltd. . All Rights Reserved.